Li-Ion battery cell impedance test (current source)

This circuit models a Li-Ion battery

Based on the following paper:

Marek MICHALCZUK1, Bartłomiej UFNALSKI2, Lech M. GRZESIAK2, Piotr RUMNIAK2
Politechnika Warszawska, Instytut Automatyki i Robotyki (1), Instytut Sterowania i Elektroniki Przemysłowej (2)

Power converter-based electrochemical battery emulator

http://pe.org.pl/articles/2014/7/3.pdf

Status:
This model replicates figure 6 in the above paper. The model is calibrated for a single 40Ah battery cell. This 40Ah calibration is represented by parameters values of 4 different blocks:
I_meas
Rsn_const
C1n_const
R1n_const

To calibrate for a given cell capacity, Capacity_cell [Ah], modify the parameters according to these relationships:

I_meas.K =
1/(Capacity_cell[Ah]*3600[s])

Rsn_const.OUTPUT_LEVEL =
3.1E-3[Ohm]*Capacity_cell[Ah]/40[Ah]

R1n_const.OUTPUT_LEVEL =
1.9E-3[Ohm]*Capacity_cell[Ah]/40[Ah]

C1n_const.OUTPUT_LEVEL =
22.75E3[Farad]*Capacity_cell[Ah]/40[Ah]

tangkongyuen@hotmail.com's picture

Points

157

Joined May 6, 2018
Design added Wednesday, May 30, 2018 | 6:37 pm PDT